Intra Oral X-Rays - BEST-X-DC with TIM-X (Palmtop) - With Mobile Stand
Intra Oral X-Rays - BEST-X-DC with TIM-X (Palmtop) - With Mobile Stand
The new Best-X-DC configuration includes the palmtop TIM – X for the control of exposure parameters.
The 0.3 mm focal spot tube allows obtaining more detailed x-ray images with any type of film, sensors and phosphor plates, reducing to a minimum the exposure time / emitted dose.
TIM-X is a state-of-the-art wireless radio-frequency palmtop which allows controlling the X-Ray Unit in total safety ensuring ease of handling.
Remote management of kilovolt [kV], milliamperes [mA], and explore time [ms], makes Best X-DC a unique device of its kind.
Exposure timing preset programs (according to R10 scale) may be customized by the end-user.
The easy manoeuvrability of the head, which is very light, enables an immediate, precise and vibration-free positioning.
Technical data | BEST-X DC with TIM X |
Classification | Class I Electro-medical Apparatus with type-B part appllied |
Head | Constant potential radiographic managed by microprocessor |
Rated electrical power | 0,800 kW |
High frequency technology | 100 KHz |
Focal spot | 0,3 mm - 0,4 mm (IEC 336) |
Absorption | 6:00 am |
Tube Toshiba | D-045 - OX/70-4 - OX/70-3 |
Ø of long cone at the end of spacer | |
Total filtration | 2 mm Al eq. |
Selectable anodic current | 4-6,5 mA |
Selectable voltage to x-ray tube | 60-70 kVp |
Dispersed radiation | ≤ 0,25 mGy/h a 1meter from focus 1 |
Exposure time | 20 ms – 1000 ms scala R10 |
Intermittent operationPower supply | 230 V ± 10% |
Intermittent operation | 1 s exposure: 30 s reset max |
Distance | F.F. 20 cm |
Fuse | F 6.3 AH |
Deadman logic control | wireless |
Intra Oral X-Rays - BEST-X-DC with TIM-X (Palmtop) - With Mobile Stand
The new Best-X-DC configuration includes the palmtop TIM – X for the control of exposure parameters.
The 0.3 mm focal spot tube allows obtaining more detailed x-ray images with any type of film, sensors and phosphor plates, reducing to a minimum the exposure time / emitted dose.
TIM-X is a state-of-the-art wireless radio-frequency palmtop which allows controlling the X-Ray Unit in total safety ensuring ease of handling.
Remote management of kilovolt [kV], milliamperes [mA], and explore time [ms], makes Best X-DC a unique device of its kind.
Exposure timing preset programs (according to R10 scale) may be customized by the end-user.
The easy manoeuvrability of the head, which is very light, enables an immediate, precise and vibration-free positioning.
Technical data | BEST-X DC with TIM X |
Classification | Class I Electro-medical Apparatus with type-B part appllied |
Head | Constant potential radiographic managed by microprocessor |
Rated electrical power | 0,800 kW |
High frequency technology | 100 KHz |
Focal spot | 0,3 mm - 0,4 mm (IEC 336) |
Absorption | 6:00 am |
Tube Toshiba | D-045 - OX/70-4 - OX/70-3 |
Ø of long cone at the end of spacer | |
Total filtration | 2 mm Al eq. |
Selectable anodic current | 4-6,5 mA |
Selectable voltage to x-ray tube | 60-70 kVp |
Dispersed radiation | ≤ 0,25 mGy/h a 1meter from focus 1 |
Exposure time | 20 ms – 1000 ms scala R10 |
Intermittent operationPower supply | 230 V ± 10% |
Intermittent operation | 1 s exposure: 30 s reset max |
Distance | F.F. 20 cm |
Fuse | F 6.3 AH |
Deadman logic control | wireless |
Standard warranty covered by the seller against any manufacturing defect. In such events, please report to us within 7 days from the date of delivery at connect@lumiere32.sg.
0 customer reviews found.
Please fill all the details
Please fill all the details
Please fill all the details
Please fill all the details
Please fill all the details
Please fill all the details
Please fill all the details
Please fill all the details