Short Description

ResMed Non-invasive Ventilator, Curative GA 614, 1 Unit

Share This Item

Maximum stable ultimate pressure?PLSmax? 40cmH2O
Minimum stable ultimate pressure?PLSmin? 4cmH2O
Maximum settable working pressure?PWmax? 40cmH2O
Minimum settable working pressure?PWmin? 4cmH2O
Limiting the maximum working pressure method.... Controlling fan speed
Reaching the minimum working pressure.................Controlling fan speed
Maximum breathing resistance in a single fault condition 60L/minhour≤4cmH2O
? Loss of power source ? 30L/min hour ≤2cmH2O
noise <40dB(A) ?Output air breathing pressure at the ventilator
It is 980Pa (10.0cmH2O) and the ambient background noise is 20dB (A), 1 meter away from the device

VOLUME.........................................................................390×355×305
WEIGHT.......................................................................... 8.4Kg?BATTERY INCLUDED?
Anti-shock type.............................................................. Class I, internal power supply
Protection against electric shock...................................B
Safety level when used in the case of flammable anesthetic gas mixed with air or flammable
anesthetic gas mixed with oxygen or nitrogen oxide------ NONE AP DEVICE
Built-in switching power supply fuse…………………………………T 4.0A?250V (Users cannot replace it by themselves)
Degree of protection against harmful ingress...............IPX1
Operating mode.............................................................continue to operate
Trigger method.............................................................. Flow / time trigger
The patient connection port conforms to the 22mm conical joint specified by YY0461.
Hyperbaric oxygen……………………………………………… Pressure?2.76-6.00 bar / 276-600 kPa /
40-87 psig
flow?180 SLPM
Connector?NIST or DISS
Low flow oxygen............................................................ under pressure of 50cmH2O, the most flow is30L/min
When the ambient background noise is 20dB (A), theloudness of the main alarm sound speaker is in the range of
60-85dB (A), and the adjustment level is5 levels.
When the ambient background noise is 20dB (A), the loudness of the auxiliary alarm buzzer is not less than 65dB
(A).
Filtering technology
Actual value: recalculated after each breath (no average value).
Average: Calculated based on the 6 most recent breath-related values since the ventilator was started.
Leakage: Calculate continuously, after each breath.
Power supply: AC 100-240V 50/60Hz 300VA
DC 12-24V----6-3A
Internal battery (optional): 14.8V 10Ah
Operating environment:
Environment temperature + 5 ? ? + 40 ?
Relative humidity 10% ? 95% (without condensation)
Atmospheric pressure 700hPa ? 1060hPa

Standard warranty covered by the seller against any manufacturing defect. In such events, please report to us within 7 days from the date of delivery at connect@lumiere32.sg.

Overall Customer Rating:

  • 0
0 customer reviews

Sign In Or Register to post your reviews. Sign Up

0 customer reviews found.


Customers who viewed this item also viewed

Request Quote

Please fill all the details


Write Review

Please fill all the details


1
2
3
4
5

Request For Pre-order

Please fill all the details


Request For Product Catalog

Please fill all the details


Request For Sample

Please fill all the details


Request For Sample/Demo

Please fill all the details


Ask More Information

Please fill all the details


Request for Quote/Pre-book

Please fill all the details


Popup content
One Item Add To List